Fault
|
Reason
|
Measures
|
Motor can not start
|
Motor voltage is too low:a.Low power supply voltage;
|
a.Will be transferred to the rated voltage rang.
b.Power cord with larger cross section.
c.Move closer to the power line position.
|
Single phase power supply(3-phase):a.Poor contact of power switch;b.Fuse fuse c.Power cord loose;d.Cable fault phase |
a.Repair switch contact or replace switch;b.Replace fuse;c.Check and tighten the power adapter;d.Repair or replace the cable
|
The cable drop is too large:a.Line is too long b. The cable section is too small
|
a.Remove excess c able
b.Cable with larger cross section
|
The capacitor burned.
|
Replace the same type of capacitance.(Send the maintenance point maintenance)
|
Shaft and bearing die
|
change bearing (Send the maintenance point maintenance)
|
Impeller stuck
|
Use the screwdriver to move the blade end shaft, the rotating flexible or open the pump body to clear debris.
|
Winding of stator broken
|
Replace winding coil (Send the maintenance point maintenance)
|
Motor running, but not water
|
Pump rotation direction is wrong
|
Conversion motor in which the two phases of the wiring (three-phase motor)
|
The pump is not filled with water
|
To pump water into the pump body.
|
damaged impeller
|
change impeller
|
The water level is lower than the bottom valve
|
Adjust the inlet pipe to pump valve in the water
|
Water suction pipe leakage
|
Check the sealing condition of each joint of the suction inlet pipe.
|
The water level is too low, which is lower than the limit of the pump.
|
Adjust the installation height of the pump or choose the appropriate pump.
|
Water in a pipe or pump chamber causes icing.
|
After the ice has been turned on.
|
Insufficient pressure
|
Pump selection is not correct.
|
Choose the right water pump.
|
The water inlet pipe is too long, or too many bends, the diameter of the water inlet pipe is not selected according to the regulation. |
Selection of the provisions of the pipe diameter, so that the design of the inlet pipe is a little shorter。
|
Foreign matter blocking inlet pipe, filtering net or pump cavity
|
Clean the pipe, valve or pump chamber to remove debris
|
Motor voltage is too low, the wire is too long
|
Check the end voltage of the motor and the cross section of the wire
|
Pump vibration
|
Pump is not fixed in the base
|
Tighten the anchor bolts
|
There is a foreign body in the pipe or pump cavity
|
Check, clean pipes and water pumps.
|
Stability of the base is not enough
|
Installation of a more stable base
|
Motor stator winding burn or intermittent work
|
Motor overload running time is too long
|
The installation of the valve outlet, reduce water
|
Impeller stuck or long time overload operation
|
Removal of impurities in the pump cavity, as far as possible in the rated flow of water pump work
|
Ground faults or cable damaged by lightning, electric pump
|
Find the reason, change the winding coil
|
Water leakage at the support
|
Mechanical seal with impurities
|
Clean or replace mechanical seals |